MA5200G Fails to Load Patch because Slave Board has no Corresponding File

Publication Date:  2012-07-27 Views:  127 Downloads:  0
Issue Description
After patch file uploads over SMU, carry out patch load all hd:/patch/ MA5200_22SP32.PAT command and it prompts patch file fails to load at slave board. Enter slave board hd: and there is no patch file. And there is no MA5200_22SP32.PAT file.
      
Alarm Information
Null 
Handling Process
1. Use mkdir slot10#hd:/patch command and creat patch file at slave board hd:/.
2. Use patch load all hd:/patch/ MA5200_22SP32.PAT command and re-load file.
3. patch active all all_patch successfully activates patch.
      
Root Cause
There is no patch file at slave board hd:. Carry out patch load all flash:/patch/ MA5200_22SP32.PAT command and copy slave board hd:/patch/ to MA5200_22SP32.PAT, which fails. Patch load fails.
      
Suggestions
Carry out command of active patch, MA5200G will copy patch file in the directory from master SMU to slave SMU. If there is no corresponding directory at slave SMU, the problem occurs. It is suggested to put patch under hardware or root directory of flash. If it is put under other directory, create corresponding directory file at slave SMU before activating the patch.

END