Alarm Message GRUB ERROR 24 Appears Due to the Corrupted File System of USB SSD Cards

Publication Date:  2012-07-22 Views:  294 Downloads:  0
Issue Description

During the startup of the storage device, the alarm message GRUB ERROR 24 displays, and the startup fails.

Product and version information:
  • S2600
Alarm Information
None
Handling Process
  1. Power off the storage device and then power it on again.
Root Cause

The file system of the USB SSD card is corrupted, causing the startup of the storage device to fail and display the alarm message GRUB ERROR 24.

Suggestions

The OS of the storage device is stored in the USB SSD card and coffer disks of controllers respectively. When the file system of the USB SSD card becomes corrupted, the storage device can be automatically booted up from coffer disks, and write the OS into the SSD card when the device boots up properly.