Elog check Eudemon 8080E session log,the log produce time and session save into DB time have a difference with 16 hours

Publication Date:  2012-11-09 Views:  259 Downloads:  0
Issue Description
In Secospace eLog log management system inquire the Eudemon 8080E session log, find the log produce time and session save into database time have a difference with 16 hours. Login firewall and check firewall configuration, and find as the same as "configure firewall" of “Seccospace eLog log management system operation guide".
Alarm Information
none
Handling Process
<Firewall> save
Modify the firewall configuration.
1. Login firewall, and enter the user view.
2. Configure firewall time zone.
<Firewall> clock timezone time-zone-name { add | minus } offset
Use Beijing time as an example: Beijing time is early with 8 hours than Eudemon 8080E FWl default UTC time, so input clock timezone c8 minus 08:00:00, if late than UTC time, the input clock timezone c8 add 08:00:00.
3. Set the date of the firewall, the date of the firewall must as the same with the log collector.
<Firewall> clock datetime HH:MM:SS YYYY/MM/DD
For example: set the date as 12:25:30 2010/10/30, then input clock datetime 12:25:30 2010/10/30.
4. Save configuration.
<Firewall> save
Root Cause
Eudemon 8080E time zone and the time configuration way is different to the other firewall, other firewall configure time zone and time following the above principle: when the local time is early than FW default UTC time, configuration command use add; when the local time is late than firewall default UTC time, configuration command use minus. And in Eudemon 8080E configuration command is just opposite: when local time is early than Eudemon 8080E FW default UTC time, configuration command use minus; when the local time is late than Eudemon 8080E FW default UTC time, configuration command use add.
Suggestions
none