Alarms in Quidway S3300 when combo-port wasn't running

Publication Date:  2013-03-16 Views:  1022 Downloads:  0
Issue Description
In our Project we have used more than 100 pcs S3300, when we do the commissioning work ,we find the following alarms
Alarm Information
Jan  1 2008 00:11:28-05:13 ACBS-AS-S3300-MAINBLDG-1F-3 SRM/3/RXPOWER_EXCEEDMINOR:OID 1.3.6.1.4.1.2011.5.25.129.2.1.9 Optical module exception, RX power too low.(EntityPhysicalIndex=67109198, BaseTrapSeverity=4, BaseTrapProbableCause=67697, BaseTrapEventType=9, EntPhysicalContainedIn=0, EntPhysicalName=GigabitEthernet0/0/4, RelativeResource=Interface GigabitEthernet0/0/4 optical module Rx Power, ReasonDescription=RX power too low) 
Handling Process
<Quidway> system-view

[Quidway] interface gigabitethernet 0/0/1

[Quidway-GigabitEthernet0/0/1] combo-port copper

Root Cause
combo-port command is used to configure optical multiplexing interface (combo interface) the optical port model with electrical interface mode switching.
By default, the automatic switch mode electrical interface mode optical port.
Suggestions
No Summary