SMC 2.0 V100R002C01B017SP08 cannnot connect MCU

Publication Date:  2014-03-31 Views:  454 Downloads:  0
Issue Description
version of SMC 2.0 V100R002C01B017SP08 often not connected to the MCU
Alarm Information
None
Handling Process
Select the encrypted connection mode according to the MCU or non-encrypted connection
Root Cause
A connection parameter is incorrect. This is the most common case, where is everyone primary query.
2 Check if entered correctly matches the model
These two points are the most easy to check, but still often not connected to the MCU in this release
The reason is: MCU connection defaults to HTTP connection SMC,

The default mode SMC MCU is added by default encryption mode, which is the HTTPS mode is the default mode does not match the place we most easily overlooked

Suggestions
1 Check whether the parameters are correct (type, connection password) SMC 2 check whether the connection mode and MCU connection pattern matching (HTTP mode is not encrypted, HTTPS encryption mode)