S5500T V1R5 the member disk cannot be located alarm

Publication Date:  2014-09-17 Views:  331 Downloads:  1
Issue Description
Version:
OceanStor S5500T V100R005

Symptom:
    There is an alarm about disk. “The member disk cannot be located; therefore, the RAID group may be degraded or faulty.”
Alarm Information
The member disk cannot be located; therefore, the RAID group may be degraded or faulty.
Handling Process
Debug method:
Check config.txt file if the disk status is reconstructed.
Root Cause
Root cause:
    Fault disk caused the disk negotiation failed, so that the disk can’t be used.
Suggestions
Solution:
Replace the disk.