No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our Private policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade
MENU

Network Connection Failure Between the SoftCo and Devices on Other Network Segments

Publication Date:  2015-04-21 Views:  218 Downloads:  0
Issue Description
IADs on different network segments cannot ping the SoftCo. The SoftCo and devices on other network segments are disconnected.
Handling Process
Step 1 Connect a PC to the network and ping other devices from the PC. If other devices can be pinged, the network works properly.

Step 2 Check whether the gateway IP address configured on the SoftCo is correct. If no, correct the gateway IP address on the SoftCo.

Step 3 In the BOOT1 or BOOT2 debugging menu, check whether the debugging network port is on the same network segment as the service network port. If yes, the service network port cannot be connected to the network. Access the BOOT menu, run the p0 command to view the current IP address of the debugging network port, and run the c0 command to change the IP address to an unused one.

----End
Root Cause
1.  The Ethernet router is not correctly configured.

2.  The gateway IP address configured on the SoftCo is incorrect.

3.  The configuration of the debugging network port is incorrect.

END