NE40 ATM interface reject cells due to incorrect ATM setting in JU router

Publication Date:  2012-07-27 Views:  45 Downloads:  0
Issue Description
One NGN exchange, uses ATM network to bearer traffic, Huawei sides uses NE40, connect to ATM switch, another side is Juniper router.
ATM side foundes NE40 rejected some cells, and we check interface information, it is true, see below.  There are discard messages in input and this value increase slowly, very slow but still increase.
<RSH-NE40>disp int atm2/0/4.1
Atm2/0/4.1 current state: up
Line protocol current state: up
  Hardware is ATM STM-1,
  Description: RSHto prepaid
  Internet address is 10.223.11.2/30 Is-Primary
  The Maximum Transmit Unit is 1500 bytes, the BandWidth is 155000 Kbits
  Input:  771896 packets, 144847790 bytes
          122 errors, 0 unknown frames, 122 discard frames
  Output: 762651 packets, 381321528 bytes
          0 discard frames
Alarm Information
It`is true, see below.  There are discard message in input and this value increase slowly, very slow but still increase.
<RSH-NE40>disp int atm2/0/4.1
Atm2/0/4.1 current state: up
Line protocol current state: up
  Hardware is ATM STM-1,
  Description: RSHto prepaid
  Internet address is 10.223.11.2/30 Is-Primary
  The Maximum Transmit Unit is 1500 bytes, the BandWidth is 155000 Kbits
  Input:  771896 packets, 144847790 bytes
          122 errors, 0 unknown frames, 122 discard frames
  Output: 762651 packets, 381321528 bytes
          0 discard frames
Handling Process
We asked Juniper side change their setting, this issue is solved.
Root Cause
Like this case, reject cells, we analysis there are below possiblities:
1. Error code in interface.
2. ATM QOS not match.
Because that interface has serveral sub-interface, others interface don't have this problem, and there is no error code alarm, so we think that is not the reason. And we request Ju side give trafic configuration, and found PCR is very high in Ju router, and according to custoemr's requirement, PCR shall be 30M, but Ju side configure to almost 270M, that's the reason. Ju side will send higher traffic to NE40 suddenly, and it exceeds to our setting, so NE40 rejects those cells.
Suggestions
We must clear concept of CBR, VBR, UBR, this is basic concept in ATM product.

END