Draw the S8016NE80NE40 products out of the interface board, the other slot interface boards NP resets abnormally

Publication Date:  2012-07-27 Views:  47 Downloads:  0
Issue Description
Draw out  the interface board, the other slot interface boards NP resets abnormally.
Alarm Information
Null
Handling Process
We can shut the interface of interface board and net board via configuring Command,and then draw the interface board out.
S8016 Command is:shut slot XX
NE80 Command is:downlpu XX
As inserting, need not any operation, open the interface of the interface board and net board directly after inserting.
Root Cause
As drawing out the interface board with service, the generated fragment packets will result in the other interface board NP abnormity.
Suggestions

Null