After the 42EFT Is Configured with Services, Reset the 42EFT to Enable the Services

Publication Date:  2012-07-24 Views:  47 Downloads:  0
Issue Description
Configure the EPL service on the 42EFT (Metro 500 or 1000) through the LCAS function. After configuration is complete, the service is disabled. Delete the service and then re-configure it. The problem remains. At last, reset (hard or soft) the EFT and then the service is normal.
Alarm Information
None
Handling Process
Follow the above specification to configure the service.
Root Cause
[ cause]
The configuration is not standard.
[analysis]
If the data board enables the LCAS function, after the service is enabled, enable the LCAS function at both the source and sink ends of the service. Namely, configure the SDH service, data service, and data attribute (except for LCAS) orderly. After both the source and sink NEs of the service are configured and the service is enabled, enable the LCAS function for the service on both the source and sink EFTs.
Suggestions
None

END