No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Line Protocol DOWN on POS Interface caused by Unmatched CRC type used between NE-40 and Cisco Cat-6500/ Juniper M10 POS Interface

Publication Date:  2012-07-27 Views:  49 Downloads:  0
Issue Description
Line protocol on both POS interface (Huawei NE-40 and Cisco Cat-6500/Juniper  M10 routers) can not UP.
Alarm Information
CRC Error counter on both side POS interface of the routers is increased significantly.
Handling Process
Configure Juniper/Cisco routers to use 32 bit CRC type.
Root Cause
Missmatched CRC type used between Huawei NE-40 router on POS Interface and Cisco/Juniper routers caused the line protocol between Huawei and Juniper/Cisco routers cannot UP.
Huawei NE-40 used 32 bit CRC type by default, since Juniper M10 and Cisco Cat-6500 used 16 bit CRC type by default.
Suggestions
CRC type used on POS interface could be shown by POS interface display information command.

END