Flow-action Cannot be Followed by the Parameter of no-pat If NE40 is Upgraded from Vrp3.10-0426 to Vrp3.10-2321

Publication Date:  2012-07-27 Views:  36 Downloads:  0
Issue Description
At a site, NE40 is upgraded to Vrp3.10-2321 from Vrp3.10-0426 , and flow-action (without no-pat) is lost in comparison of configurations.  NAT is problematic.
Alarm Information

Null

Handling Process
Add the commands lost manually one by one. 
Root Cause
After the equipment is upgraded , flow-action is not being followed by the parameter of no-pat, resulting in lost of configuration of no-pat. 
Suggestions
It's necessary to compare the configuration after upgrade.

END