FAQ-How to Check the QOS Information of NE80 NE40 S8016

Publication Date:  2012-07-27 Views:  46 Downloads:  0
Issue Description
Q: How to check the QOS information of NE80 NE40 S8016?
Alarm Information
Null
Handling Process
In debugging and diagnosis mode, 8011 products provides the following helpful commands for information query and location of problem:  [Quidway-diag]efu qos query slot-id     ---> checks the number of nodes that apply EACL at specific unit [Quidway-diag]efu qos hit-count eacl    ---> checks the matching of specific EACL [Quidway-diag]efu qos police-count eacl --->checks the matching of specific EACL as CAR [Quidway-diag]efu qos display           ---> checks the position of one node with EACL rule in EACL rule tree in microcode. 
Root Cause
Null
Suggestions
Null