FAQ-How to Check the Routing Mode of LPU Unit of NE40

Publication Date:  2012-07-27 Views:  40 Downloads:  0
Issue Description
Q: How to check the routing mode of LPU unit of NE40?
Alarm Information
Null
Handling Process
A: Execute the following command in diagnosis mode: 
  [NE40-diag]display lpu lpupara 2 (slot-number)
 Start to Display Lpu flash parameter of 02...
[NE40-diag]
Slot No. 2 Info is:
   LPU Param:
 FSU_VERSION : Release version
 FSU_DEBUG_COMM : Debug through serial port
 FSU_NETSTATUS1 : Net1 is online
 FSU_NETSTATUS2 : Net2 is online
 FSU_WATCH_DOG : Watch dog is working
 FSU_NPS_STATICS : NPS collect statistics
 FSU_BUILDRUN : Buildrun is on
 FSU_EPLD0 : EPLD0 is up-to-date
 FSU_EPLD1 : EPLD1 is up-to-date
  FSU_ROUTE_TAB : Large route table  (it is large route table mode)
 FSU_RAINIER_VER :   31
 FSU_RULE_MODE : Status of RULE Config Mode is RANGE mode
 FSU_PARA12 : Reserve
 FSU_PRODUCT_FLAG : NE40
 FSU_24BIT_EXT1 : CPOS 24Bit Extension Mode is E1 mode
 FSU_PARA15 : Reserve
[NE40-diag]display lpu lpupara 2<slot number>
 Start to Display Lpu flash parameter of 02...
[NE40-diag]
Slot No. 2 Info is:
   LPU Param:
 FSU_VERSION : Release version
 FSU_DEBUG_COMM : Debug through serial port
 FSU_NETSTATUS1 : Net1 is online
 FSU_NETSTATUS2 : Net2 is online
 FSU_WATCH_DOG : Watch dog is working
 FSU_NPS_STATICS : NPS collect statistics
 FSU_BUILDRUN : Buildrun is on
 FSU_EPLD0 : EPLD0 is up-to-date
 FSU_EPLD1 : EPLD1 is up-to-date
 FSU_ROUTE_TAB : Small route table  (it is small route table mode)
 FSU_RAINIER_VER :   31
 FSU_RULE_MODE : Status of RULE Config Mode is RANGE mode
 FSU_PARA12 : Reserve
 FSU_PRODUCT_FLAG : NE40
 FSU_24BIT_EXT1 : CPOS 24Bit Extension Mode is E1 mode
 FSU_PARA15 : Reserve
Root Cause
Null
Suggestions
Null