No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Physical Layer of E1-F Port of AR28-40 Is not Up Because of Difference in Timeslot Configuration of Equipment at Both Sides of E1 Link

Publication Date:  2012-07-27 Views:  30 Downloads:  0
Issue Description
Symptom: Physical layer of E1-F port of AR28-40 is not up. 
Topology: AR28-40----2M----ROUTER. E1-F port of the router has five timeslots including 1, 3, 4, 5, and 7. E1-F port of AR28-40 uses 1-31 timeslots by default. 
Alarm Information
Null
Handling Process
Change the configurations for E1-F of AR28-40 and encapsulate the timeslot of 1, 3, 4, 5, and 7, solving the problem. 
Root Cause
The problem is caused by difference in timeslot configurations of equipment at both sides of E1 link. 
Suggestions
Null

END