FAQ-How to Troubleshoot that the Patch does not Take Effect after NE5000E/80E/40E Is Resetted

Publication Date:  2012-07-27 Views:  43 Downloads:  0
Issue Description
Q: How to troubleshoot that the patch does not take effect after NE5000E/80E/40E is resetted?
Alarm Information
Null
Handling Process
1. Check if the path cfcard: contains "patchstate.dat" file; if not, it may be deleted by mistake. Re-run the patch. 
2. Check if the patch file "pu.pat" has been copied to standby MPU; if not, the system will reset, and the standby MPU cannot load the patch normally. 
Root Cause
Null
Suggestions
Null

END