Active/Standby Switchover Fails Because the Startup File for Standby MPU Is Configured Falsely

Publication Date:  2012-07-27 Views:  36 Downloads:  0
Issue Description
Active/Standby switchover fails because the startup file for Standby MPU Is configured falsely, and the standby MPU repeats resetting. 
Software version: VRP3.10-2317 . The case is suitable for NE40/80, and S8016 at VRP3.10-2XXX.
Alarm Information
The setting for startup file when failure occurs is as follows: 
 <NE40-4>disp bootload                                                    Boot file on flash is: flash:/8011V100R002B03D017SP03USR.bin .                   Boot file on hard disk is: hd:/8011V100R002B03D017SP03USR.bin.                  hd is the default boot device.                                                <NE40-4>disp bootload slave                                              Boot file on flash is: flash:/8011V100R002B03D017SP03USR.bin.                   Boot file on hard disk is: hd:/8011V100R002B03D017SP03USR.bin.   Flash is the default boot device. 
Handling Process
1. Power off the equipment and draw out the active MPU.
2. Power on the equipment and start up it, waiting for startup of MPU to execute bootload from hd {filename} command in user view. 
3. Set the startu file saved on harddisk, and then plug the original active MPU into the equipment. 
4. Once the MPU is started, synchronize the data and perform active/standby switchover. 
If the equipment carries services and it cannot reset the whole system, you can log into the standby MPU through console port of standby port during its reset, and open bootrom menu to revise the startup file. 
Root Cause
The causes include: 
1. The software versions for both MPUs differ. 
2. The startup file of standby MPU is problematic (the size of files differ).
3. The startup file for standby MPU is set falsely. 
4. The hardware of standby MPU is problematic. 
The cause of the case is: the default startup equipment for standby MPU is "flash", but "flash" does not contain the file named "8011V100R002B03D017SP03USR.bin", so the MPU cannot synchronize the data; the active/standby switchover fails, and the standby MPU repeats resetting. 
Suggestions

Null