FAQ-How to Start MPU of NE5000E/80E/40E

Publication Date:  2012-07-27 Views:  40 Downloads:  0
Issue Description
Q: How to start MPU of NE5000E/80E/40E?
Alarm Information
Null
Handling Process
A: During the startup of MPU of NE5000E/80E/40E, the printing information includes big software system, small software system and application program. In the small software system, any failure in initialization will reset the LPU. If Sarting... is promted, it means that the small software system finishes startup, and press Ctrl + A to enter the menu for small software system, which is mainly for upgrade of big and small software systems. Once Booting from CFcard... occurs, it needs to start application program from CF card, till the whole system is started. When it prompts Press ENTER to get started, it could respond to the entering of external command after a while. 
Root Cause
Null
Suggestions
Null