FAQ-How to Connect the Optical Fibers of NE80/40 to Form RPR Ring

Publication Date:  2012-07-27 Views:  44 Downloads:  0
Issue Description
Q: How to connect the optical fibers of NE80/40 to form RPR ring? 
Alarm Information
Null
Handling Process
A: Correct connection of optical fibers of NE80/40 RPR is very important, and they must form a ring  for normal working;  otherwise, if the fibers are connected falsely, the ring will not be available even though the configure of LPU is correct. 
For example: 
For one RPR ring with n nodes (n>=2) as N1, N2,..., Nn, their direct optical fibers are connected as follows: 
1. Make the A side of node N1 idle. 
2. Connect the transmitting/receiving port of B side of node N1 to that at the A side of node N2. 
3. Connect the transmitting/receiving port of B side of node N2 to that at the A side of node N3. 
...
n.  Connect the transmitting/receiving port of Bside of node N(n-1) to that at the A side of node Nn. 
n+1. Connect the transmitting/receiving port of Bside of node Nn  to that at the A side of node N1. 
Note: Both A and B sides of RPR LPU with double subcard must be in the two continuous slots, and the one in odd slot must be at first. For example,  slot 1 and slot 2, slot 3 and slot 4, etc. , of which the one in odd slot is A side, and the one in even slot is the B side. Pay attention to the numbering order  of slots of NE80/NE40 series routers, particularly NE40-4 and NE40-2, of which the slots are numbered from the bottom to top,  so the LPU at down side is the A side, and that above is B side. 
Root Cause
Null
Suggestions
Null

END