No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-What Is the Difference in LDP Neighbor Setup of NE80/NE40 between V3.1 and V3.3

Publication Date:  2012-07-27 Views:  57 Downloads:  0
Issue Description
Q: What is the difference in LDP neighbor setup of NE80/NE40 between V3.1 and V3.3? 
Alarm Information
Null
Handling Process
A: For NE80/40 at VRP3.1, two equipment could set up multiple LDP neighbors through direct-connected interfaces. For the consideration of interconnection with equipment from C company, VRP3.3 is changed to that only one LDP neighbor could set up between two devices, through loopback interface address by default. If two neighbors are set, one is valid, and the other will be denied. 
Root Cause
Null
Suggestions
Null

END