The Physical Layer Is Up and the Link Layer Is Down in Interconnection of NE40 with M20 of J Company through 155M POS

Publication Date:  2012-07-27 Views:  41 Downloads:  0
Issue Description
The physical layer is up and the link layer is down in interconnection of NE40 with Juniper M20 through 155M POS. 
Alarm Information
#Oct 31 02:06:41 2005 HIHK-PB-RT02 SRM/5/LineAlarmOk:OID=1.3.6.1.4.1.2011.2.17.0
.126,Index=134217990,SlotNum=2,SubCardNum=0,PortNum=0,line alarm indication sign
al recover!                                                                     
#Oct 31 02:06:42 2005 HIHK-PB-RT02 SRM/2/B2DftErr:OID=1.3.6.1.4.1.2011.2.17.0.14
7,Index=134217990,SlotNum=2,SubCardNum=0,PortNum=0, signal defect bit error rate
!                                                                               
#Oct 31 02:06:42 2005 HIHK-PB-RT02 SRM/5/DataOutLockOk:OID=1.3.6.1.4.1.2011.2.17
.0.140,Index=134217990,SlotNum=2,SubCardNum=0,PortNum=0, receive data out of loc
k recover!                                                                      
#Oct 31 02:06:42 2005 HIHK-PB-RT02 SRM/5/PathOk:OID=1.3.6.1.4.1.2011.2.17.0.132,
Index=134217990,SlotNum=2,SubCardNum=0,PortNum=0, path alarm indication signal r
ecover!                                                                         
#Oct 31 02:06:42 2005 HIHK-PB-RT02 SRM/5/PathDftOk:OID=1.3.6.1.4.1.2011.2.17.0.1
34,Index=134217990,SlotNum=2,SubCardNum=0,PortNum=0, path remote defect indicati
on recover!                                                                     
#Oct 31 02:06:43 2005 HIHK-PB-RT02 SRM/5/B2DftOk:OID=1.3.6.1.4.1.2011.2.17.0.148
,Index=134217990,SlotNum=2,SubCardNum=0,PortNum=0, signal defect bit error rate 
recover! 
Handling Process
Change the  value of C2 at NE40 to 0xcf, as follows: 
SDH overhead:(Rx/Tx)                                                            
  F1  : NA/NA    , J0  : 0x01/0x30, K1  : 0x00/0x00, K2  : 0x00/0x00            
  S1  : 0x00/0x08, C2  : 0xcf/0xcf, F2  : NA/NA    , Z3  : NA/NA                
  Z4  : NA/NA    , V5  : NA/NA 
After the changes, the protocol layer of POS is up, and the problem is solved. 
Root Cause
1. No parameter is problematic through checkup, but CRC is not found, so it may be because CRC coding differs. Huawei defaults it to 32 which cannot be changed; Juniper M20 defaults it to 16. After query, Juniper M20 has been 32. 
2. It is doubted that optical fiber or optical interface is problematic, but the problem persists after replacement of those devices. 
3. Check the parameters of interface: 
SDH overhead:(Rx/Tx)                                                            
  F1  : NA/NA    , J0  : 0x01/0x4e, K1  : 0x00/0x00, K2  : 0x00/0x00            
  S1  : 0x00/0x08, C2  : 0xcf/0x16, F2  : NA/NA    , Z3  : NA/NA                
  Z4  : NA/NA    , V5  : NA/NA 
It is found that the value of C2 cannot match. The protocol layer may be up even though the value of C2 does not match, but the value of C2 of equipment from J company has the meaning of without adding scramble, so the interfaces interconnected must be the same. 
Suggestions
Pay attention to negotiation parameters in interconnection of equipment, especailly in the connection with equipment of other vendors'. 

END