FAQ-How to Check the C2-Byte of POS Interface

Publication Date:  2012-07-27 Views:  52 Downloads:  0
Issue Description
Q: How to check the C2 byte of POS interface of NE40/80 POS? 
Alarm Information
Null
Handling Process
A: C2-byte is for signals, and it is a byte of Higher-Order Path Overhead, indicating the nature of multiplexing structure of Virtual Container (VC) frame, and the nature of information net load. Generally, the link LED will not be bright if the C2-byte of POS interface of Huawei produts differs to that of remote equipment, but the services are normal. 
In system view, execute display pos interface Pos X/X/X command to check. 
For detail, see the following: 
[NE40:21]disp pos interface Pos 3/0/3
Pos3/0/3 current state: up
Line protocol current state: up
  Physical layer is Packet over SDH
  Card info: POS OC-3c/STM-1-MM-SR-MTRJ
 ................................
SDH overhead:(Rx/Tx)
  F1  : NA/NA    , J0  : 0x00/0x4e, K1  : 0x00/0x00, K2  : 0x00/0x00
  S1  : 0x00/0x08, C2  : 0x22/0x16, F2  : NA/NA    , Z3  : NA/NA
  Z4  : NA/NA    , V5  : NA/NA
................................
Note: 
Like the C2 byte in the above information, "0x22" in "C2  : 0x22/0x16" is the C2 byte of the equipment at peer, and "0x16" is the one of local device. 
The bytes are of hex, but they are typed in decimal in setting, so pay attention to the translation. 