OSN3500 equipment the alarm POWER_ABNORMAL's parameter meaning that SSN1SCC board repot

Publication Date:  2012-07-24 Views:  35 Downloads:  0
Issue Description
The field engineer tell us that them can not understand  the explanation for POWER_ABNORMAL alarm of OSN3500 equipment in the commissioning guide.
OSN3500 host check 10-channel voltages, which are AUX board-3.3V, standby power supply-3.3V, this board-3.3V, this board power module-3.6V, this board-2.5V, this board-1.8V, this board-5V, standby power supply after slow launching-3.3V(V33_BAKIN), A-channel -48V and B-channel -48V, respectively. Alarm parameters are shown below: 
para[3] 0~7
[0]    AUX3V fault
[1]    3VBAK fault
[2]    V33 fault
[3]    V36 fault
[4]    V25 fault
[5]    V18 fault
[6]    V5 fault
[7]    V33_BAKIN fault
para[4] 0~1
[0]    A-channel -48V
[1]    B-channel -48V
For example,there is an alarm of POWER_ABNORMAL display bellow:
257579 18 POWER_ABNORMAL MJ end 2006-3-8 14:7:45  2006-3-8 14:7:46 
0xff        0xff        0xff        0x10      0x00
para[0]   para[1]   para[2]   para[3]   para[4]
The parameter 
Here the para[3] value is 0x10,value is 16,it is out of the range of value wide 0~7,but R&D expert tell us 0x10 meaning that the V25 is fault,according to the define of the parameter,it is para[3] “[4] V25 fault”.   
Alarm Information
POWER_ABNORMAL
Handling Process
The commissioning document explanation is unclear, parameter should be described as bellow:
para[3]  bit0~bit7
bit [0]    AUX3V fault
bit [1]    3VBAK fault
bit [2]    V33 fault
bit [3]    V36 fault
bit [4]    V25 fault
bit [5]    V18 fault
bit [6]    V5 fault
bit [7]    V33_BAKIN fault
para[4]  bit0~bit1
bit [0]    A-channel -48V
bit [1]    B-channel -48V
Furthermore,the alarm parameter is order from para[0],not order from para[1].The correctly comprehend is as below denotation.
0xff        0xff        0xff        0x10      0x00
para[0]   para[1]   para[2]   para[3]   para[4]
Root Cause
After discuss with R&D expert, we understand why. Every parameter have one byte(8 bit) long, HEX:0x00;BIN:0000 0000;  every bit express one type of power alarm, if the value is 0 meaning the power is normal,if the value is 1 means the power is fault. 
For example: 
if the para[3] value is 0x11 HEX,BIN value is B(0001 0001),it means AUX3V fault and V25 fault.
Suggestions
This problem has the case No:1388870.
This case help engineer correctly comprehend the parameter of power_abnormal, and some basic concept.

END