Question about Board N1SLH1

Publication Date:  2012-07-24 Views:  41 Downloads:  0
Issue Description
Customer wants to know about this type of board, what happens if he inserts a N1SLH1 board in the slot 17... According to manuals the EU08 Should be inserted 
in Slots 35 and 36, in order to protect the N1SLH1 we should insert it the slot 18, now the question is... do I need to insert two TSB8 (Slots 37 and 38) in order to 
perform the TPS ??? Or only I need one TSB8 ?? See the picture attached....
      
Alarm Information
No alarms
      
Handling Process
If you want to protect 16-channels you should use two TSB8. and the configuration is OK. N1SLH1 Slot 17 (W), N1SLH1 Slot 18 (P). EU08 in slot 35, 36.
      
Root Cause
In your case you are trying to provide a protection 1:1 TPS.
When the equipment is configured as SLH1 with 16-channel 1:1 TPS, you should install two TSB8 in the slots 37 and 38 and the EU08 in the slots 35 and 36, exactly like you did.
      