No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

NE40-4 router's configuration after LPUF sub-board plug-out

Publication Date:  2012-07-27 Views:  36 Downloads:  0
Issue Description
If plug-out LPUF sub-board from NE40-4 router without poweroff or preliminary router configuration (using "downlpu" command), the previous configuration of GE interfaces is still present on router.      
Alarm Information
No any alarms; the previous configuration of GE interfaces is still present on router.
Handling Process
Used command "downlpu" before plug-out LPUF sub-board. After plug-out LPUF, use command "undo downlpu".
      
Root Cause
Software and hardware feature.
Suggestions
Before plug-out LPUF sub-board, use command "downlpu". After plug-out LPUF, use command "undo downlpu".The information about NE40 router's LPU boards operation (plug-out and plug-in operations) is absent in NE40's technical manual. The information about types of hot-swap and hot-plug LPU boards is absent in technical manual also. The description about modules present only. So, you should discuss with other engineers and try to get maximum help which you can reach.      