FAQ-A approximate formular for calculating MSP switching time

Publication Date:  2012-07-24 Views:  68 Downloads:  0
Issue Description

A approximate formular for calculating MSP switching time

Alarm Information
None
Handling Process
As you may know, the K1K2 bytes in the Overhead Section of SDH frames play an important role during MSP switching. A rough estimation of switching time is as 
follow: the main control board receives signal failure (SF) after 3ms, 2ms for each line card to report K1K2 bytes, 1.8ms for each node to perform cross switch. In addtion, an unstable factor 
deviation is also taken into account. Thus, an approximate formular for the switching time is given as:
Switching time = switching detection time + K byte transmission time + cross switch time + fiber transmission time + unstable factor deviation = 3 + (N/2 + 1)*2ms + (N/2 + 1)*1.8ms + x + y
where, N is the number of nodes on the ring, x = 3/2*(whole ring distance / speed of light), y is the possible deviation caused by unstable factor, value scope is 0~3.8ms, the speed of light in glass is 200,000 km/s
For a ring network with 6 nodes covering 100 km, the switching time is: 3 + 8 + 7.2 + 0.75 + 3.8 = 22.75 ms
            
Root Cause
None
Suggestions
None

END