OSN3500 remote mangement is down because the multi-ports line board occupied the ECC resource

Publication Date:  2012-07-24 Views:  36 Downloads:  0
Issue Description
we have two OSN 3500 connect to each other through two STM-64 (1+1 MSP)and one STM-1 link .when fiber of slot 8 is unplugged , we loose communication with remote site although the service is ok.
 
OSN Software version is :5.36.13.44
Alarm Information
NE Login Fail
Handling Process
open T2000:
from the DCC mangement menu on NE Explorer
disable the SDH interfaces that is not used as aggregate line to connect to the remote stations (SLT1 Card), so there will be enough DCC bytes to be used for 
aggregate lines
      
Root Cause
      we found the service is carried through SLT1 card which has 12 STM-1 ports, this card reserved all DCC bytes as the maximum Bytes can be used is 120 Byte for OSN .
Suggestions
 in such cases where the NE has many optical interfaces check the DCC channel allocation either by T2000 or by Command Line :
:cm-get-dccpara; :cm-get-bdinfo;

END