How to transfer the alarm information on BITS to SNMP NMS

Publication Date:  2012-07-24 Views:  38 Downloads:  0
Issue Description
The field engineer started the SNMP testing and recieved the following error during testing:
the alarm observed on the NE is "MITU source difference exceeds threshold". and the alarm reported on the MIB NMS is "enterprise ID not found (see Details) 1.3.6.1.4.1.2011.2.75.3.17.3.13
Alarm Information
Enterprise ID not found.
Handling Process
the customer engineer made the resolution mapping table,then the alarm can be reported via SNMP NMS normally.
Root Cause
1.If the customer want to transfer the alarm information on BITS to SNMP NMS such as TeMiB,they should firstly make the resolution mapping table,then the alarm will be resolved normally.the customer engineer should know how to make the resolution mapping table.
2.Regarding the alarms and its relation to mib files,you can get the contents from the file named as HUAWEI-BITS-MIB.my.For example,
-- 1.3.6.1.4.1.2011.2.75.3.17.3.13
trapNtpDist NOTIFICATION-TYPE.
OBJECTS { hwBitsTrapType, bdCfgBoardIndex, bdCfgType, hwAlarmId, hwAlarmTime, 
hwAlarmSN, hwCasuseId, hwTrapType }
STATUS current.
DESCRIPTION .
" MITU source difference exceeds threshold.
"
::= { almMinor 13 }
It is means the alarm OID is 1.3.6.1.4.1.2011.2.75.3.17.3.13 and the description of this alarm is "MITU source difference exceeds threshold".
Suggestions

None.