The IP of the BITS has been reseted to default after power off

Publication Date:  2012-07-24 Views:  48 Downloads:  0
Issue Description
While doing the PAT for BITS equipment - "Configuration restoration after equipment power Off and Power On", the SynLock Terminal Computer cannot ping BITS equipment. Before power off the eqipment 
could responded to ping.
            
Alarm Information
Whem send the ping command to the BITS's IP address, a BITS cannot response to ping.
Handling Process
1. Connect the COM port through the COM cable
2. Modify the IP address to the appropriate one according to the project design information.
Root Cause
1.The IP configuration of MITU board is backuped into two section individually.If IP is configured by CON port on MITU,the IP configuration will be backuped into BIOS, 
if configured by maintenance terminal,the IP configuration will be backuped into BIOS and system configuration section at the same time.
2.When you query IP configuration by the maintenance terminal the data alway be derived from the system configuration section.But when the equipment is powered 
on, the IP configuratio will be derived from BIOS.
3.The current debugging procedure in factory had some problem,firstly the board will be test at circuit board modulating Dept.,the worker will configure the ip as 10.75.
14.1 by maintenance termina,so the ip in BIOS and system configuration section is 10.75.14.1,when debugging the integrated equipment the worker will  configure 
the ip as 10.75.19.46 by CON port,so the ip in BIOS is modified as 10.75.19.46 and the data in system configuration section is 10.75.14.1.
4.We think someone queried the ip configuration by maintenance terminal,the ip will be 10.75.14.1 although the actual ip should be 10.75.19.46,then the guy 
confirmed the configuration  inadvertently.After power off and on, the modification takes effect.
5.R&D promises to modify the debugging procedure in factory,the data in different working procedure will be consistent.
      
Suggestions