NE80E and C Corporation's Device Connect Multicast VPN and it is Unreachable

Publication Date:  2012-07-27 Views:  52 Downloads:  0
Issue Description
The topology can be referred to the attachment. Check multicast VPN building with multicast software. After the configuration is finished, the service cannot be normally established and multicast VPN cannot be built. Check the route of NE80E and there is no opposite *.SG. The service cannot be normally established.
Alarm Information
Null
Handling Process
1. disp dev and the board is GRE.
2. Check mtunnel address configuration and it is unnumbered address.
3. Check whether the first interface of GRE is set as loopback local and it is found there is no configuration. Configure loopback local, multicast VPN is set up normally and the multicast software of both sides displays normally.
Root Cause
1. Multicast VPN service need use GRE board. For NE80E product, change LPUA board of 10XGE as GRE.
2. Before configuring multicast VPN service, first set the first interface of GRE as loopback local and then make configuration of multicast VPN. Otherwise the service is not enabled.
3. For mtunnel configuration, the address should be actual address and it cannot be unnumbered address. Otherwise the service is not reachable.
Suggestions
Null