There is Alarm on NE80&NE40&S8016 and the Network Board has no Heartbeat

Publication Date:  2012-07-27 Views:  42 Downloads:  0
Issue Description
There is much abnormal alarm on S8016 device.
Alarm Information
HDLC alarm indication is as follows:
%Mar 11 09:24:50 2006 FXXXDL-HUAWEI-NE80-2 SRM/5/Net low level info:The master/slave register of Net board 19 is mater status, the master/slave register of Net board 20 is slave status, switch mode is CONTROL mode.
#Mar 11 09:24:55 2006 FXXXDL-HUAWEI-NE80-2 SRM/1/HDLCChannelWarn:OID=1.3.6.1.4.1.2011.2.17.0.82,Slot19 HDLC channel warning!
#Mar 11 09:24:57 2006 FXXXDL-HUAWEI-NE80-2 SRM/5/HDLCChannelOk:OID=1.3.6.1.4.1.2011.2.17.0.83,Slot19 HDLC channel warning cleared!
solid error alarm indication is as follows:
#6/20/2006 17:31:8-SRM-1-SolidWarn:OID=1.3.6.1.4.1.2011.2.23.11.2.0.64,SFC20 solid error!
#6/20/2006 17:31:9-SRM-1-SolidWarn:OID=1.3.6.1.4.1.2011.2.23.11.2.0.64,SFC20 solid error!
#6/20/2006 17:31:10-SRM-1-SFCFail:OID=1.3.6.1.4.1.2011.2.23.11.2.0.80,SFC20 failed!  
Handling Process
Change bootrom chip of V300 version.
The way to check bootrom version:
           NETB network board:  "test net command <slot No> dn"
           SFCB network board:  "test sfc command <slot No> dn"
e.g. read network board information of NE80 19 slot:
[s8016-diag]test sfc command 19 dn
 SFC execute the command is ok.
 SFC return result:d061018ae640SI2DRV04040705SI_V2R01D1-l04yy
 
Matching relation of displayed version and document software version:
V1R01D3-lst: V100
V2R01D1-l03: V200
V2R01D1-l04: V300
Root Cause
For bootrom version, during the use of V100 bootrom there is conflict between host software protocol frame and  the protocol frame of the board itself, which results in HDLC alarm. The alarm itself does not influence the service, but the heartbeat packet of the network board may be lost. There is HDLC alarm for V200 software, but the alarm number is less than V100 and will not influence its normal use. Swap or reset the board once, there is no HDLC alarm. V300 can solve the problem.
Suggestions
Null

END