No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

NE40E Power Supply Module State is Abnormal

Publication Date:  2012-07-27 Views:  41 Downloads:  0
Issue Description
Phenomenon: Power supply is normal, but displaying state is not normal:
17        PWR     Present   NA            Abnormal    NA        
18        PWR     Present   NA            Abnormal    NA        
[NE40E]display alarm all 
----------------------------------------------------------------------------
Level          Date        Time                Info      
Error        06-08-03    16:01:35    power monitor cable unplugged 
---------------------------------------------------------------------------- 
Alarm Information
17        PWR     Present   NA            Abnormal    NA        
18        PWR     Present   NA            Abnormal    NA        
[NE40E]display alarm all 
----------------------------------------------------------------------------
Level          Date        Time                Info      
Error        06-08-03    16:01:35    power monitor cable unplugged 
---------------------------------------------------------------------------- 
Handling Process
Check it according to the analysis. It belongs to the first one. Swap the cable and the problem is solved.
Root Cause
Cable: UNPLUG does not check PBOK  signal.
There is one power supply backplane at the bottom of the box. There is Z12 terminal, 24pin. The terminal includes monitoring signal of power supply and 48V voltage to fan.
1 pin and 24 pin are PBOK. They are connected on backplane of power supply. They are not handled.
The system realizes cable check by checking whether there is short  ciucuit of these two pins. When the cable is plugged, two PBOK signals are connected and it displays the cable is normal.
There are possible reasons of the alarm:
1. The cable is not plugged or one cable is disconnected.
2. Two PBOK signals on backplane are not connected (The copper is disconencted.)
3. The cable of MPU is problematic.
There is detailed example figure.
Suggestions
Null

END