There is Abnormal Alarm Information after NE80E Upgrades

Publication Date:  2012-07-27 Views:  55 Downloads:  0
Issue Description
NE80E upgrades from v300r001b02rsp02 to v300r001b02wsp08. After upgrade check version has no mismatch item, but the alarm prompts Paf/License absent or error.
Alarm Information
The alarm prompts Paf/License absent or error.
Handling Process
There is rainier board on the device. But on the spot paf and lisence of withoutrainier are used. The alarm prompts Paf/License absent or error. Reload paf and lisence of withrainier and the problem is solved.
Root Cause
1. Paf and lisence are problematic through alarm information.
2. Check whether the size of Paf and Lisence matches that of loaded Paf and Lisence.
3. Check the device uses rainier or not. If it is used, use paf and lisence of withrainier.
Suggestions
Whether there is rainier board before deployment or upgrade. Choose correct Paf and Lisence.

END