NE20E Prints Assertion Information

Publication Date:  2012-07-27 Views:  16 Downloads:  0
Issue Description
NE20E version 5.30 23122002, it prints the following information:
%Aug 31 10:04:26 2006 Quidway VOS/5/ASSERT:slot:0,                              
%2006-08-31 10:04:25-VOS-ASSERT:slot:0,Task:SRM(TID:21)                         
Assert at file: '../../../../product/8060/ne20/app/ssu/dev20e/fltchk/fltchk_main
.c', Line: 555                                                                  
                                                                                
Call Stack:                                                                     
StackBase  ReturnIns  FuncEntry                                                 
 05E2C0F0   0031845C   FFFFFFFF  UnKnown!                                       
 05E2C6F0   01E0B150   FFFFFFFF  UnKnown!                                       
 05E2C710   01E0A868   FFFFFFFF  UnKnown!                                       
 05E2C730   01E0A63C   FFFFFFFF  UnKnown!                                       
 05E2C770   01E0A484   FFFFFFFF  UnKnown!                                       
 05E2C980   01DBDD44   FFFFFFFF  UnKnown!                                       
 05E2C990   01DBD6AC   FFFFFFFF  UnKnown!                                       
 05E2C9C0   00389CA8   FFFFFFFF  UnKnown!                                       
 05E2C9F0   02175F0C   FFFFFFFF  UnKnown!
Alarm Information
Null
Handling Process
Plug GE board in slot 1 and 2 and then the assertion disappears.
Root Cause
The engineer plugs GE board in slot 7 and 8. HIC card can plug in slot 1, 2 and 4.
Suggestions
Null