No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

HP-TIM, HP-LOM and HP-UNEQ alarms on line boards

Publication Date:  2012-07-24 Views:  59 Downloads:  0
Issue Description
After cutover (integration one OSN 2500 to existing network) HP-TIM, HP-LOM and HP-UNEQ alarms appeared on line boards on Metro 1000.
szhw>
:alm-get-curdata:0,0
@@@@@@@@@@@@@@@@@ Message from 0x00090001 (9.0.1 589825)  @@@@@@@@@@@@@@@@@@
                                                                                                              
                                                  ALM SUMMARY                                                 
  NUM         BID   EID         SEVE        STATE       START-TIME           END-TIME             PARAS       
  14502       11    HPTIM       minor       start       2006-9-15 0:55:32    None                 0x01ffff01  
  14503       11    HPTIM       minor       start       2006-9-15 0:55:32    None                 0x02ffff01  
  14504       11    HPTIM       minor       start       2006-9-15 0:55:32    None                 0x03ffff01  
  14505       11    HPTIM       minor       start       2006-9-15 0:55:32    None                 0x04ffff01  
  14507       11    HPLOM       major       start       2006-9-15 0:58:39    None                 0x03ffff01  
  14508       11    HPLOM       major       start       2006-9-15 0:58:39    None                 0x04ffff01  
  14510       11    HPUNEQ      minor       start       2006-9-15 0:58:43    None                 0x03ffff01  
  14511       11    HPUNEQ      minor       start       2006-9-15 0:58:43    None                 0x04ffff01  
  Total records :8  
Alarm Information
HP-TIM, HP-LOM, HP-UNEQ.
Handling Process
1. Configured at least one VC-12 path in each VC-4 (1,2,3 and 4) and HP-LOM and HP-UNEQ alarms disappeared.
2. After configuration at least one VC-12 path in each VC-4 we could manage content of J1 byte. Set it as usual as "HuaWei SBS " and HPTIM alarms dissappeared.
Root Cause
1. After alarms analizing it turned out that HP-LOM and HP-UNEQ alarms are reported on tnat VC-4 which are not loaded with traffic. 
2. Also when VC-4 is unloaded you cannot configure J1 byte to exclude HP-TIM.
Suggestions
If HP-TIM, HP-LOM and HP-UNEQ alarms are reported on line boards: 
1) configure at least one VC-12 channel in each VC-4.
2) configure J1 byte as "HuaWei SBS     " on each station.

END