There is Great Loss When Two E1 Links are Enabled MP Bundling and One E1 Link is Shutdown

Publication Date:  2012-07-27 Views:  40 Downloads:  0
Issue Description
Topology:
NE40-1 and NE40-2 are interconnected through two E1 links and they are enabled MP bundling.
Phenomenon:
1. Shutdown one E1 link  on NE40-1 and NE40-2 configuration does not change. When NE40-1 pings NE40-2 or NE40-2 pings NE40-1, there is great loss at the first one minute and the loss reaches 50%. And then there is no loss.
2. Shutdown one E1 link  on NE40-2 and NE40-1 configuration does not change. When NE40-1 pings NE40-2 or NE40-2 pings NE40-1, there is great loss at the first one minute and the loss reaches 50%. 
Alarm Information
Null
Handling Process
NE40 E1 link reports that the protocol is down when ten Hold time packets are not received. The interval of one Hold time packet is 10s. The interval of ten Hold time packets is 100s. About two minutes it regards that the link is down. Within 100 seconds, e.g. NE40-1 shutdown one E1 port, NE40-2 regards that E1 link is down for 100s. NE40-2 sends packet to E1. So the problem occurs.
Set Hold time short (The default is 10s.)
Root Cause
NE40 E1link handling is problematic.
Suggestions
Null