FAQ-Guide to configuring the maximum service access capacity of the OptiX OSN1500 V001R200

Publication Date:  2012-07-24 Views:  40 Downloads:  0
Issue Description
The maximum service access capacity of the OptiX OSN1500 V001R200 can be listed as following (only support one at a time):
1) 5xSTM-16 standard or concatenated service
2) 18xSTM-4 standard or concatenated service
3) 42xSTM-1 standard service
4) 18xSTM-1 (electrical) service
5) 8xE4 service
6) 12xE3/DS3 service
7) 126xE1/T1 service
8) 20xFast Ethernet (FE) service
9) 6xGigabit Ethernet (GE) service
10) 12xSTM-1 ATM service
11) 3xSTM-4 ATM service
How to configure the OSN1500 V001R200 with each service (assuming that the boards such as AUX[10], PIU[18,19], FAN[20] are already installed).
Alarm Information
None.
Handling Process
The following summarizes the configurations of the OSN1500 V001R200 that have maximum service access capacities for each service in the form: Board_Type[Slot position]
1) SL16[11-13], CXL16[4,5]
2) SLQ4[11-13], CXL4[4,5], R1SL4[6-9] (Only R1SL4 board can be used in Slot 6,7,8,9 because of their limited access capacity of 622 Mbit/s)
3) R1SLQ1[1-3,6-9,11-13], CXL1[4,5]
4) SEP1[11-13], EU08[14,16], CXL1/4/16[4 or 5]
5) SPQ4[12,13], CXL1/4/16[4 or 5]
6) PD3[12,13], D34S[14,16], CXL1/4/16[4 or 5]
7) PQM[12,13], D12S/B[14-17], CXL1/4/16[4 or 5]
8) EFS0/EMR0[12,13], EFS4[11], ETF8/ETS8[14,16], CXL1/4/16[4 or 5]
9) EGS2[11-13], CXL1/4/16[4 or 5]
10) ADQ1[11-13], CXL1/4/16[4 or 5]
11) ADL4[11-13], CXL1/4/16[4 or 5]
Root Cause
None.
Suggestions
None.

END