Our customer wants to know what does he need to configure on the NE40 router (VRP 5.1) to get output of a command without having to type space to every more.

Publication Date:  2012-07-27 Views:  38 Downloads:  0
Issue Description
Customer wants to know what does he need to configure on the router to get output of a command without having to type space to every more.
Customer said that he was needed to set the length of the terminal to infinite as the output that need to be taken is very long and, due to current setting, it takes a lot to get the data
      
Alarm Information
Handling Process
Configure command "screen-length 0" under user-interface view. 
For example:
user-interface vty 0 4                                                             
 screen-length 0   
But please pay attention, when using this command, when router need display lots of information in a moment, the CPU of the router maybe very high, so please just use this command when really necessary.
      
Root Cause
Usage requirment.
Suggestions

END