Configuration Points for Huawei Device Connecting with the Device of C Enterprise through POS

Publication Date:  2012-07-27 Views:  38 Downloads:  0
Issue Description
Our device connects with the device of C enterprise through POS. The entity layer is up, but Line Protocol is down.
display interface pos 1/0/0
Interface pos 1/0/0
Pos1/0/0 current state : UP
Line protocol current state : DOWN
Alarm Information
Null
Handling Process
For this case, it is our new device. The client requires us to refer to parameters of C enterprise and configuration is as follows:
interface Pos1/0/0 
 link-protocol hdlc
 description CHT STM-1 Link to ABC-C7603
 control-flap
ip address X.X.X.X 255.255.255.252
 undo scramble
clock slave
crc 16
display interface pos 1/0/0
Interface pos 1/0/0
Pos1/0/0 current state : UP
Line protocol current state : UP
Description : CHT STM-1 Link to ABC-C7603, Route Port
The Maximum Transmit Unit is 4470 bytes, Hold timer is 10(sec)
Internet Address is X.X.X.X/30
Link layer protocol is nonstandard HDLC
The Vendor PN is TRP-03L3I1BCHWS
Port BW: 155M, Transceiver max BW: 155M, Transceiver Mode: SingleMode
WaveLength: 1310nm, Transmission Distance: 15km
Physical layer is Packet Over SDH
Scramble disabled, clock slave, CRC-16, loopback: none
Flag J0 "NetEngine       "
Flag J1 "NetEngine       "
Flag C2 22(0x16)
    SDH alarm:
        section layer:  none
        line    layer:  none
        path    layer:  PRDI
    SDH error:
        section layer:  B1 0
        line    layer:  B2 0  REI 0
        path    layer:  B3 647
Statistics last cleared:2006-09-27 17:31:48
Root Cause
Default parameters of Huawe company and those of C enterprise are different and details are as follows:
1. C enterprises uses encapsulation HDLC, but our device uses protocol ppp.
2. C enterprises uses pos scramble, but our device uses scramble.
3. C enterprises uses crc 16, but our device uses crc 32.
4. C presets clock  as slave (C enterprise clock source=line) and it depends on present situation. If there is intermediate transmission device, clock of both sides is set as slave. If the fiber is directly connected, the clock of one side is set as master and that of another side slave.