The Interface Synchronization Is Influenced by the Changes to the Mode of NE80E 24 XGE Sub-interface

Publication Date:  2012-07-27 Views:  32 Downloads:  0
Issue Description
NE80E version: VRP5.30-31002S.03
Symptoms: The mode of sub-interface of ETH_24XGE_CARD is changed,  and it influences the mode of interface. 
Alarm Information
Null
Handling Process
1. Set the mode of interface of ETH_24XGE_CARD to 100M full duplex. Use display this command to check the configuration information of duplex; use display interface (such as G10/0/0) command,  and we can know that the interface works at 100M full duplex; use display interface sub-interface (such as G10/0/0.100) command,  and we can know that the interface still works at 100M full duplex. Enter the sub-interface,  and execute display this command,  but we cannot find the configuration of 100M full duplex,  but the sub-interface has the options as speed 10,  100,  auto and duplex 10,  100 and auto. Changing the mode of sub-interface makes that of interface change also. 
2. In NE80E,  the sub-interface of ETH_10XGE_CARD does not have speed,  duplex and negotiation auto,  undo negotiation auto commands.
3. In other routes as AR46,  the sub-interface does not have the similar commands like speed,  duplex and negotiation auto,  undo negotiation auto.
Root Cause
Null
Suggestions
The mode should be set in interface, and the sub-interface should remove the setting for working mode, avoiding that mis-operation can influence the state of interface. For the setting of interface of NE80E, pay attention to the influence of sub-interface configuration on interface.