No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FAQ-Can CON of MPU on NE80E Access the Terminal and Make Related Operation

Publication Date:  2012-07-27 Views:  42 Downloads:  0
Issue Description
Q:
Can con of MPU on NE80E access the terminal and make related operation?
        
 
Alarm Information
Null
Handling Process
A:
NE80E defaults that there is no output when Con of slave MPU accesses the terminal. There is no operation on the terminal. HOwever, login on the system and change default setting with the following command:
[Quidway-hidecmd]slave  command-line  accessible
And then the terminal accesses Con of slave MPU on NE80E and the command can be executed.
NE40E and NE5000E are similar to NE80E.
Root Cause
Null
Suggestions
It is suggested that the operation of configuration should be operated on master MPU.
 
 

END