Configuring ECC communication over

Publication Date:  2012-07-24 Views:  52 Downloads:  0
Issue Description
When you have TPS function enable on SEP board, if the bytes D4-D12 are being used to manage the end line equipments, if the working board fails, the end line equipments get down from the management.
      
Alarm Information
NE_COMMU_BREAK
NE_NOT_LOGIN
Handling Process
After configure "DCC Resource Allocation" by T2000 to use 10xD1-D3 and 10xD4-D12 bytes, you must configure the DCC port of protection SEP by navigator. Use the commands:
- To check the configuration:
   :cm-get-ohpchan:bid,portid;
   bid: figure(_UC);
   portid:figure(_UC);
   SAMPLE:
   :cm-get-ohpchan:2,3;
- To add DCC rate to the protection SEP board:
   :cm-add-ohpchan:bid,portid,chantype,protoid;
   bid: figure(_UC);
   portid:figure(_UC); 
   chantype: D1-D3 or D4-D12 or D1-D12;
   protoid: ip, osi, hwecc, auto;
   SAMPLE:
   :cm-add-ohpchan:2,3,D1-D3,osi;
Root Cause
The DCC bytes are not configured on the protection board, and there is no way to configure it by T2000.
It is necessary to use Navigator.
Suggestions
 