Service Board cannot be Registered because NE80E Host Software has CRC

Publication Date:  2012-07-27 Views:  45 Downloads:  0
Issue Description
NE80E expands POS service board that cannot be registered.
       
Alarm Information
Related alarm in logffer is as follows:
%Dec 12 10:51:08 2006 BJ-ZGC-NE40E-B SRM/5/Startmode:LPU3 report startmode:unkno
wn startmode!.                                                                  
Download of software to LPU board on slot 3 has failed                          
LPU on slot 3 occurs error, error Code:1, Error message:file's crc error.       
Total 1 file(s) matched, 0 file(s) download to 3 LPU.                           
Download file(ID/Index):20101a60/161                                            
%Dec 12 10:51:10 2006 BJ-ZGC-NE40E-B LOAD/5/LOADRESULT:LoadResult:              
Download of software to LPU board on slot 3 has failed                          
LPU on slot 3 occurs error, error Code:1, Error message:file's crc error.       
Total 1 file(s) matched, 0 file(s) download to 3 LPU.                           
Download file(ID/Index):20101a60/161                                            
Download of software to LPU board on slot 3 has failed                          
LPU on slot 3 occurs error, error Code:1, Error message:file's crc error.       
Total 1 file(s) matched, 0 file(s) download to 3 LPU.
Handling Process
1. Swap and change slot. It is still problematic,
2. Plug the LPU board on NE80E of the same version and it can be registered and the test service is normal. POS LPU board is not problematic and the host program of the version also supports it.
3. From the alarm downloaded program of expanded POS board is problematic error and the error type is CRC. It is possible that large packet program of NE80E is problematic.
4. Download large packet program of NE80E and check it with CRC. There is error. 
5. Load the program without CRC error and the problem is solved.
Root Cause
1. The host program of the version does not support the LPU board.
2. The service board is problematic.
3. NE80E is problematic.
Suggestions
Ensure the program is not problematic before loading it. Use the tool in the attachment to check.