No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

LP alarms don't interrupt the service

Publication Date:  2012-07-24 Views:  44 Downloads:  0
Issue Description
      According to ITU-T, all low path alarms should send AIS downstream. In the NG-SDH equipments, it doesn't happen.
      
Alarm Information
LP_TIM
LP_UNEQ
LP-PLM
      
Handling Process
Nothing can be done. The insertion of AIS si disable on NG-SDH equipments because of historical problems.
Root Cause
All NG-SDH software is configured to not insert AIS downtream. This decision had been taken because of historical problems.
Suggestions
As the customer complained about this "out of standard" function, it should be intersting if this function could be configurable, like HP_TIM, HP_UNEQ and  HP_PLM.
This technical case should be accepted to inform another engineers if they face the same problems.

END