No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

disconnection on STM-1 link caused by the dust on the connector

Publication Date:  2012-07-27 Views:  65 Downloads:  0
Issue Description
in the ADSL network the backbone core network is NE40 routers, the interconnection between this two router NE40 is ok the ping is ok also but  when the traffic increase we found some disconnection  and packet lost 9% .
Alarm Information
Null
Handling Process
check with ping to the host form two side , loopback .
when the traffic increase we check again by the same way,
check the fiber ,check the connector (change them and see if there is difference).
clean the connector by recommanded tools and method.
the problem is solved after that.
Root Cause
we did check the that interface is up ,protocol is up ,so link is ok .
the transsmission is (STM-1 link throught transsmission equipement).
when we did check the fiber connector ,we found little dust .
when the traffic increase the temperature increase in optical modul on the interface so the dust will have more effect and create noise on the signal.
Suggestions
always you need to do routine check for the equipement hardware and software ,this is proactive measure action and can show you the problem before happening.

END