NODEB of 3G cannot Obtain the Clock Because the Clock Parameter of NE40 Is Incorrectly Set

Publication Date:  2012-07-27 Views:  22 Downloads:  0
Issue Description
Networking:
CPOS interface of NE40-OSN-3G NODEB
NE40 obtains the clock from OSN and NODEB obtains the clock from NE40.
1. After the transmission OSN and the optical interface of NE40 are connected, there is pointer adjustment alarm on transmission network management.
2. NODEB on CPOS interface of NE40 cannot obtain the clock.
3. The clock mode and clock source of NE40 are incorrect.
         Current source: 0 
         Clock is in hold mode  
       
Alarm Information
1. There is pointer adjustment alarm on transmission network management.
2. NODEB cannot obtain the clock.
3. Error packets occur on SE of NE40.
Handling Process
1. Check the transmission and there is no error.
2. NODEB version has no such defect.
3. Ping local interface and there is no error packet.
4. Check CPOS interface and configure the clock as slave. There is no problem.
5. Check the master clock board DISP DEVICE 9.
   The clock source and clock status are incorrect.
    Current source: 0 
    Clock is in hold mode  
    After the clock slave  is configured, the pointer is still adjusted. The precision of line clock is not precise enough and the jitter exceeds the range. Use the clock board to lock the clock and improve the precision of the clock.
6. Change the configuration.
    Take SSM from the line board.
   clock sour 3 force off
   clock sour 4 force off
    Change the clock reference source in the master clock board.
   clock manu sour 3 slot 9
    The problem is rectified.
            
Root Cause
1. The transmission quality is low and E1 bit error rate is great.
2. NODEB version.
3. NE40 interface.
4. NE40 clock is incorrectly set.
Suggestions
Null

END