FAQ-Why PCB Version of the LPU Is Different When ME60 Upgrades the Same Software Version

Publication Date:  2012-07-27 Views:  56 Downloads:  0
Issue Description
Q:
Why PCB version of the LPU is different When ME60 upgrades the same software version?
      
Alarm Information
Null
Handling Process
A:
After the ME60 of the same delivery upgrades the same software version. Run the display version command. The PCB version of the LPU is different.
 <me60-cx-1>dis version                                                          
Huawei Versatile Routing Platform Software                                      
VRP (R) software, Version 5.30 (ME60 V100R005C01B023)  
......                                       
LPU version information:                                                      
1. PCB      Version : CR52LPUA REV D                                          
 <me60-kj-1>dis version                                                          
Huawei Versatile Routing Platform Software                                      
VRP (R) software, Version 5.30 (ME60V100R005C01B023) 
......                                          
LPU version information:                                                      
1. PCB      Version : CR52LPUA REV E  
The software version cannot result in the change of PCB version. PCB is the printed board and PCB version is the hardware version. If PCB version is displayed different, the hardware may be different.              
      
      
Root Cause
Null
Suggestions
For the ME60 of VRP5.30, run the check version command to check the configuration of BootRom and logic. If there is no incompatible information displayed, no configuration of version mismatch exists.