No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

ETH_48XGE_CARD registered and unregistered by itself

Publication Date:  2012-07-27 Views:  31 Downloads:  0
Issue Description
Slot1 card of ISB-NE40E-B1 which is of type ETH_48XGE_CARD registered and unregistered by itself.
On checking the log I found the following statement.
%Aug 20 23:40:33 2007 ISB-NE40E-B1 MEM/5/WARNING:Slot=1;
Note: Detail informations already in exception buffer item0.
%Aug 20 23:40:33 2007 ISB-NE40E-B1 MEM/5/WARNING:Slot=1;
Agent info:
Current exception task is suspended!
1 exception items need printing
%Aug 20 23:40:33 2007 ISB-NE40E-B1 MEM/5/WARNING:Slot=1;"y-m-d": 2007-8-20 hr:23 min:40 sec:33 tik:78
It's MACHINE CHECK EXCEPTION
Exception Vector Number is:0x200
TaskID:34, PID:4294967295, CpuID:4294967295
%Aug 20 23:40:33 2007 ISB-NE40E-B1 MEM/5/WARNING:Slot=1;
Exception Instruction Address is:0xf3cc7c
%Aug 20 23:40:33 2007 ISB-NE40E-B1 MEM/5/WARNING:Slot=1;
Exception StackBase Address is:0x2d143e0
%Aug 20 23:40:33 2007 ISB-NE40E-B1 MEM/5/WARNING:Slot=1;
Register MSR Value is:0x10b030
%Aug 20 23:40:33 2007 ISB-NE40E-B1 MEM/5/WARNING:Slot=1;
TaskName is:SOCK
%Aug 20 23:40:33 2007 ISB-NE40E-B1 MEM/5/WARNING:Slot=1;
Show CallStack:
      
Alarm Information
Null
Handling Process
The board has to be replaced to solve this problem.
Root Cause
According to R&D this problem is cpu 7447A apparatus invalidation analysis of the materials of the 7447A chip, it is found that the materials contain alpha-emitting isotope such as thorium, uranium, and plumbum. As the alpha-emitting isotope of the chip eradiates alpha particles, if the alpha particles hit the memory unit of the cache in the CPU, data error is caused and BIT transient occurs. 
In terms of IT, this problem is called RAM soft failure, which is an innate defect of RAM. 
This problem occurs in a little probability but cannot be avoided.
After problem occur contact R&D and replace the card
Suggestions
Null      