After the Layer 2 Board and Switch 65 Are Connected, the Indicators of the Interfaces on Switch 65 Are Off

Publication Date:  2012-07-27 Views:  52 Downloads:  0
Issue Description
When testing the interworking between the NE40 and switch 65, you can find that the indicators of the NE40 are On and that the indicators of switch 65 are Off if the interfaces of the NE40 and the interfaces of switch 65 are connected through the optical fibers. The NE40 adopts the Layer 2 board, and the interfaces are GE and single module. The interfaces of switch 65 are GE single module. Run the dis int command to check the interface, and you can find that the interfaces of the NE40 are Up; 1000 Mbit/s interfaces adopt the auto negotiation mode and work in full-duplex mode; the interfaces of switch 65 are Down. The version of the NE40 is V3.1, R2351; the version of switch 65 is V3.1, R3037P01.
            
Alarm Information
Null
      
Handling Process
1. After the module is replaced, the problem still occurs. Import the loop on the NE40, and you can find that the two indicators of the interfaces on the NE40 are On. Import the loop on switch 65, you can find that the two indicators of the interfaces on switch 65 are On. Thus, problem about the physical layer is excluded.
2. Check the configuration. Configure the negotiation auto command on the NE40, and you can find that the indicators of the interfaces on both the devices are On. Using the dis int command to check the interfaces on the two devices, you can find that the interfaces are Up; the 1000 Mbit/s interfaces on both ends adopt the auto negotiation mode and work in full-duplex mode.
            
Root Cause
1. The module or the tail fibers are problematic.
2. The configuration is problematic.
            
Suggestions
1. The 1000 Mbit/s interfaces on the NE40 adopt the non-auto negotiation mode.
2. Troubleshoot the faults layer by layer from the lowest layer.
      