Bandwidth Monitoring problem on NE80E

Publication Date:  2012-07-27 Views:  58 Downloads:  0
Issue Description
XXX customer Install NE80E . Version of NE80E is VRP (R) software, Version 5.30 (NE40E&80E V300R002C02B21B).
Customer created Two subinterface on GE 9/0/3.
But when they try to monitor bandwidth on MRTG ( Bandwidth monitoring software) they find no response, and they can monitor bandwidth of subinterfaces.
They can monitor the bandwidth of other interfaces with the same software but the problem is only with subinterfaces.
 
            
Alarm Information
Null
            
Handling Process
First we check how much bandwidth is allocated to Client and this was 16 Mb and he was using almost 6 Mb but when we check the stats on interface than we find the wrong stats.
If we check  traffic on  subinterfaces there is very small traffic but on GE interface there is very large traffic 
 we check this using command :
<ISB-PE-NE80E-A>disp int gi 9/0/2
GigabitEthernet9/0/2 current state : UP
Line protocol current state : DOWN
Description : HUAWEI, Quidway Series, GigabitEthernet9/0/2 Interface, Route Port
The Maximum Transmit Unit is 1500 bytes, Hold timer is 10(sec)
Internet protocol processing : disabled
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 0018-821b-ccac
The Vendor PN is FTRJ1319P1BTL
Port BW: 1G, Transceiver max BW: 1G, Transceiver Mode: SingleMode
WaveLength: 1310nm, Transmission Distance: 10km
Loopback:none, full-duplex mode, negotiation: enable, Pause Flowcontrol:Enable
Statistics last cleared:never
  Last 30 seconds input rate: 1163400 bits/sec, 561 Packets/sec
  Last 30 seconds output rate: 4695584 bits/sec, 639 Packets/sec
  Input: 57169196157 Bytes, 315169716 Packets
  Output: 302240662721 Bytes, 337979577 Packets
  Input:
    Unicast: 307573775, Multicast: 440176
    Broadcast: 7155765, JumboOctets: 6774728
    CRC: 0, Symbol: 0
    Overrun: 0 , InRangeLength: 0
    LongPacket: 0 , Jabber: 0,  Alignment: 0
    Fragment: 0, Undersized Frame: 0
    RxPause: 0
 Output:
    Unicast: 337974114, Multicast: 0
    Broadcast: 5463, JumboOctets: 27450054
    Lost: 0, Overflow: 0, Underrun: 0
    TxPause: 0 
 
<ISB-PE-NE80E-A>disp int gi 9/0/2.1
GigabitEthernet9/0/2.1 current state : UP
Line protocol current state : UP
Description : Business-Plus-04-10-2007, Route Port
The Maximum Transmit Unit is 1500 bytes, Hold timer is 10(sec)
Internet Address is 117.20.23.137/30
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 0018-821b-ccac
Encapsulation dot1q Virtual LAN, Vlan number 1
The Vendor PN is FTRJ1319P1BTL
Port BW: 1G, Transceiver max BW: 1G, Transceiver Mode: SingleMode
WaveLength: 1310nm, Transmission Distance: 10km
Loopback:none, full-duplex mode, negotiation: enable, Pause Flowcontrol:Enable
  Last 5 minutes input rate 0 bytes/sec, 0 packets/sec
  Last 5 minutes output rate 0 bytes/sec, 0 packets/sec
  Input: 2792 packets, 502861 bytes
         2416 broadcasts, 0 multicasts
         0 errors, 0 drops, 0 unknown protocol
  Output:3877 packets, 305332 bytes
         262 broadcasts, 0 multicasts
         0 errors, 0 drops 
 
<ISB-PE-NE80E-A>disp int gi 9/0/2.2
GigabitEthernet9/0/2.2 current state : UP
Line protocol current state : UP
Description : Imzak-16Mbps-22-oct-07, Route Port
The Maximum Transmit Unit is 1500 bytes, Hold timer is 10(sec)
Internet Address is 117.20.23.141/30
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 0018-821b-ccac
Encapsulation dot1q Virtual LAN, Vlan number 1
The Vendor PN is FTRJ1319P1BTL
Port BW: 1G, Transceiver max BW: 1G, Transceiver Mode: SingleMode
WaveLength: 1310nm, Transmission Distance: 10km
Loopback:none, full-duplex mode, negotiation: enable, Pause Flowcontrol:Enable
  Last 5 minutes input rate 218 bytes/sec, 2 packets/sec
  Last 5 minutes output rate 11 bytes/sec, 0 packets/sec
  Input: 7290554 packets, 563102323 bytes
         7075334 broadcasts, 43245 multicasts
         0 errors, 0 drops, 0 unknown protocol
  Output:212830 packets, 90498194 bytes
         593 broadcasts, 0 multicasts
         0 errors, 0 drops 
After complete Examining of configuration we find that the problem relate with the sub-interface traffic statistic, not the MRTG's showing problem; 
If want to monitor traffic of GE sub-interfaces we should enable subinterfaces statistic : like:
please using command under sub-interface view: 
[NE40E-5-GigabitEthernet6/0/0.1]enable subinterface statistic 
By doing this problem was resolved.
Root Cause
XXX customer can monitor bandwidth of all interfaces except the subinterfaces. 
After complete Examining of configuration we find that the problem relate with the sub-interface traffic statistic, not the MRTG's showing problem; 
If want to monitor traffic of GE sub-interfaces we should enable subinterfaces statistic : like:
please using command under sub-interface view: 
[NE40E-5-GigabitEthernet6/0/0.1]enable subinterface statistic 
By doing this problem was resolved.
            
Suggestions
i think this should be enabled by default.
[NE40E-5-GigabitEthernet6/0/0.1]enable subinterface statistic 

END